index index > catalogue > Solenoids > Simple effect linear solenoids > ECH series (Pull or push ; High duty ; IP40)


catalogue



ECH series (Pull or push ; High duty ; IP40)

Characteristic

.Standard voltage:
 
 
VDC ( 6; 12; 24; 48; 100; 125; 205 )
VAC ( 110; 230 )
 
.Electromagnets protection rate: 
 
IP40
.Connector protection rate:
IP65 (EN60529)
.Insulation class: 
 
B (130°C)
.Work:
 
 push/pull
.Related files:
 
.Incorporated return spring:
ECH40-10 & ECH50-16

ECH65-15, ECH75-20 and ECH90-25  only under demand

 
 
*Other values of force, stroke, duty cycle, dimensions etc, can be consulted.
*The dimensional drawing is shown under voltage.
 

 

Type
Stroke
 “s” (mm)
Duty Cycle ED%
Absorbed power at 20°C (W)
 Magnetic Force (N)
Total weight(Kg)
Documentation
Beginning of stroke
End of stroke
Dimensional drawing
Curve Force-Stroke
Datasheet
ECH40-10
10
100
40
25
15
5
13
30
45
75
210
9.5
18
23
30
50
10.4
16
19.5
27
43
0.250
ECH50-16
16
100
40
25
15
5
19
45
68
120
325
18.5
30
41
56
92
44
84
104
133
193
0.750
ECH65-15
15
100
40
25
15
5
30
75
110
185
545
46
73
91
118
177
152
199
252
303
385
1.7
ECH75-20
20
100
40
25
15
5
48
110
165
265
755
57
93
114
150
258
159
245
298
363
524
3
ECH90-25
25
100
40
25
15
5
55
125
190
300
900
85
126
163
205
341
265
379
501
578
837
5.2
ECH110-45
45
100
40
25
15
5
76
175
260
420
1260
75
150
165
240
460
550
730
800
940
1300
7.3
ECH150-40
40
100
40
25
15
5
120
290
460
750
2200
250
480
580
780
1300
1100
1500
1850
2200
2800
21
Type
Stroke
 “s” (mm)
Duty Cycle ED%
Absorbed power at 20°C (W)
 Magnetic Force (N)
Total weight(Kg)
Documentation
Beginning of stroke
End of stroke
Dimensional drawing
Curve Force-Stroke
Datasheet

 info NAFSA, reserves any possibility of modification.

preguntaSend us an enquiry

back back